Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Cardiovasc Surg (Torino) ; 58(5): 643-649, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-25996842

RESUMO

BACKGROUND: Endovascular repair of ruptured abdominal aortic aneurysms (RAAAs) has been previously reported to reduce mortality rates compared to open repair. Newer stent-grafts may provide even better results with applicability in a larger number of patients. We present our experience with the Medtronic Endurant endograft over a three-year period. METHODS: Consecutive cases of RAAAs which have been managed with the Endurant stent-graft were recruited from three centers and were analyzed retrospectively. Twenty-three patients (22 males; mean age 74±9 years) were treated between June 2010 and May 2013. RESULTS: The technical success rate was 100% with no intraoperative endoleaks. Thirty-day mortality was 13% (3/23 patients). Two patients required prolonged hospitalization and mechanical ventilation. For the remaining 18 patients, the average hospitalization length was 5.5 days. Two major risk factors were found to be significantly associated with increased mortality: low systolic blood pressure on arrival at the hospital (63±6 vs. 99±22; P=0.01), and post-operative development of an abdominal compartment syndrome (Relative Risk - RR=13.3, 95% confidence interval - CI: 1.6-106; P=0.03). Other important clinical variables which did not significantly affect mortality included age (mean age 83±9 years in those who died vs. 73±9 years in the survivors; P=0.09), type of graft (bifurcated vs. aorto-uni-iliac; RR=2.2, 95% CI: 0.3-15; P=0.4), aneurysm diameter (11±4 cm vs. 9±2 cm; P=0.28), and proximal neck angulation (68±14 vs. 57±26 degrees; P=0.5). A proximal neck angulation >75° was not associated with a higher mortality rate (RR=1.33, 95% CI: 0.22-7.8; P=1). CONCLUSIONS: Endovascular repair of RAAAs resulted in high technical success and low mortality rates in this series of patients treated with the Endurant stent graft. Hypotension on arrival to the hospital and development of an abdominal compartment syndrome were predictive of increased risk of death. Patient age, aneurysm diameter and graft configuration did not negatively impact survival. Non-compliance with the device instructions for use (IFU) did not adversely affect results in this small patient series. Larger studies are needed to confirm our results.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/mortalidade , Ruptura Aórtica/fisiopatologia , Pressão Sanguínea , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Grécia , Humanos , Hipotensão/mortalidade , Hipotensão/fisiopatologia , Hipertensão Intra-Abdominal/mortalidade , Hipertensão Intra-Abdominal/fisiopatologia , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...